Outputs Tab

An Output is a physical relay or digital output that actually opens or closes a valve. Each zone can have one or more outputs triggered simultaneously when the zone runs. Press + Add Output to add one.

Output Settings

FieldDescription
NameLabel shown on the dashboard (e.g. O0, Valve A)
Valve TypeNORMAL_OPEN — relay energised to close valve (de-energised = water flows); NORMAL_CLOSED — opposite polarity
Active HighToggle ON if the relay module triggers on a HIGH signal; OFF for LOW-active boards
Show on DashboardWhen ON, the relay state (ON/OFF) is visible on the main zone card
ScannerWhich connected IO Scanner or relay board controls this output (e.g. N8D_OUT ID:2)
Scanner IO TypeCommunication protocol: MODBUS (RS-485) or DIRECT (GPIO)
Scanner Sub IDThe specific relay channel on the scanner board (e.g. [2] OUT02)

How to Wire an Output

  1. Open the Outputs tab inside the zone configuration page.
  2. Tap "+ Add Output". A new Output 1 block appears.
  3. Enter a name (e.g. O0) and set the Valve Type to match your solenoid valve wiring.
  4. Enable "Show on Dashboard" so you can see the relay state from the home screen.
  5. Select the Scanner board and the specific channel (Scanner Sub ID) for this valve.
  6. Press Save. The output is now linked to this zone.

See the Wiring Quick Reference for the physical connections behind each option.